DRX
DRX MINIFLEX II
Source: Copper
Angle range: 0 to 120 °
Method according refinement quantization by the Rietveld method
ICDD database / JCPD
SEB-EDX Environmental Scanning Electron Microscope (ESEM) coupled to an energy dispersive X-ray microprobe (EDX)
High vacuum and low vacuum mode for conductive and insulating samples – Secondary and backscattered electron detector (for chemical and topographical contrast) – Semi-quantitative EDX chemical analysis (peak mode, cartography, element detection down to Boron)
LC - MS - MS Liquid phase chromatography coupled to an Electron Impact Ionisation or Single Quadrupole Mass Spectrometer
GC - MS Gas phase chromatography coupled to an Electron Impact Ionisation or Single Quadrupole Mass Spectrometer
PTV - S/SL Injector, SIR Single Ion Monitoring Mode, Electron Impact Ionisation, Quadrupole Analyser, 82 vial autosampler
GC-FID Gas phase chromatography coupled to a FID Flame Ionisation Detector PTV Split/Splitless Injector
PTV - S/SL Injector, 82 vial autosampler
ATD Thermal Desorber
Automated Thermal Desorber, 50 sample autosampler
HS-TRAP Headspace with trap
Static headspace sampler, 40 vial sample tray
LIC Liquid Ionic Chromatography
ICP - MS ICP-MS Spectrometer equipped with a Dynamic Reaction Cell (DRC)
Quadrupole, detection threshold down to ppt, HF solution Teflon injection system, isotopic ratio
ICP AES ICP Atomic Emission Spectrometer, Double Axially and Radially Viewed
Simultaneous system, HF solution Teflon injection system, highly charged matrix injection system, organic solution analysis
Spark Spectroscopy Stationary Optical Emission Spectrometer (OES) or Spark Spectrometer for metal analysis
Iron base, Aluminium base, Copper base.  Block analysis: surface area over 1cm2 and thickness greater than 0.5 mm.
Element Analyser C / S, N / O and H Element Analyser
C / S analysis by dry combustion and infra-red detection, N / O analysis by thermal conductivity and infra-red detection, H analysis by combustion and thermal conductivity measurement
FTIR Fourier Transform Infrared Spectrophotometer
Measurement range 7500 to 370 cm-1, resolution < 1 cm-1, diamond ATR crystal
DSC Heat flow differential scanning calorimetry (DSC)
Temperature range: ambient to 450  C, Heating Speed from 0.01 to 100 °C / min
NMR Bruker 300, 500 and 600 MHz NMR spectrometer
5 mm Broad Band Inverse probe (BBI), Z gradient ATMA probehead, HR-MAS 4 mm dual 1H / 13C probe, temperature unit for recording from 200 to 400 K.
Mass Spectrometer MALDI-TOF and MicrOTOF-Q Mass Spectrometer
Electrospray, exact mass determination, MS/MS isotopic analysis